№ | The name of indicators | Brand | ||||||
КВр-0,3 К.В. | КВр-0,4 К.В. | КВр-0,75 К.В. | КВр-0,3 ЛЖ.В. | КВр-0,4 ЛЖ.В | КВр-0,3 Гн.В. | КВр-0,4 Гн.В | ||
1 | type | hot water, vertical, fire-tube | ||||||
2 | Supply voltage | 50 Hz 220 or 380V * | ||||||
3 | Rated heating capacity, MW | 0,3 | 0,4 | 0,75 | 0,3 | 0,4 | 0,3 | 0,4 |
4 | Coolant parameters: | |||||||
-allowable pressure, no more, MPa | 0,3 | |||||||
-temperature, no more, °С | 95 | |||||||
5 | Efficiency, not less % | 81 | ||||||
6 | Installed power of the electric motor, kW (smoke exhauster) | 1,5 | 1,5 | 2,2 | 1.5 | 1.5 | 1.5 | 1.5 |
7 | Exit to operating mode, min., no more | 60 | ||||||
8 | Fuel used | assorted coal, firewood, peat briquettes | liquid heating oil | natural gas | ||||
9 | Fuel consumption | |||||||
- solid fuel kg/hour, no more | 54 | 69 | 122 | |||||
- liquid furnace fuel kg / hour, no more | 28 | 39 | ||||||
- natural gas m3/h, no more | 31 | 42 | ||||||
10 | Safety valve, pcs | 2 | ||||||
11 | Overall dimensions, mm., no more | |||||||
-length | 2100 | 2100 | 2700 | 2100 | 2100 | 2100 | 2100 | |
-width | 2300 | 2300 | 2990 | 2300 | 2300 | 2300 | 2300 | |
-height (without chimney and valves) | 2400 | 2800 | 3050 | 2400 | 2800 | 2400 | 2800 | |
12 | Boiler weight, no more, kg | 1270 | 1350 | 2700 | 1270 | 1350 | 1270 | 1350 |
13 | The level of mechanization and automation, the technical process of obtaining hot water by the boiler,%, (supply and combustion of fuel - manually) | 50 | ||||||
14 | Service life, years, not less | 6 | ||||||
15 | Concentration of harmful substances in the workplace (CO content), mg/m3, no more | 20 | ||||||
16 | The noise level at the workplace does not exceed dBA | 76 | ||||||
17 | Availability ratio | 0,75 | ||||||
18 | Feed water requirement: | |||||||
-suspended matter, mg/l, no more | 5 | |||||||
-transparency along the ring, cm | 50 | |||||||
-total hardness, mg eq/l, no more | 5 | |||||||
-hardness carbonate, mg. eq/l, no more | 3 | |||||||
-iron content, mg/l, no more | 0,1 | |||||||
-oxygen content, mg/l, no more | 0,03 | |||||||
-H, pH units, no more | 8 |
The boiler is delivered to the consumer partially disassembled complete with mounting parts.
The boiler consists of:
Regardless of what fuel the system is running on, the principle of operation of a hot water boiler is the same: the fuel is burned in the firebox, and through its walls, heat is transferred to the water circulating through the heating pipes. The design of hot water boilers is created in such a way as to ensure the fullest possible combustion of fuel and optimal heat transfer.
Hot water boiler burners differ depending on the type of fuel used. They can be built-in atmospheric, or replaceable supercharged. Built-in burners require only a certain type of fuel to be used. Replaceable burners are more convenient because they allow you to switch from one type of fuel to another.