№ | The name of indicators | unit. | Brand | |||||
КВа-0,3 Гн | КВа-0,6 Гн | КВа-0,8 Гн | КВа-0,3 ЛЖ | КВа-0,6 ЛЖ | КВа-0,8 ЛЖ | |||
1 | type | Stationary, horizontal, flame tube, three-way | ||||||
2 | Supply voltage | 50 Hz 220 or 380V * | ||||||
3 | Rated heating capacity | MW | 0,3 | 0,6 | 0,8 | 0,3 | 0,6 | 0,8 |
4 | Fuel consumption | |||||||
- gas | m3/h | 36,5 | 64,5 | 86 | - | |||
- liquid heating oil | kg/h | - | 30 | 63 | 85 | |||
5 | Coolant parameters: | |||||||
- allowable pressure, no more | MPa | 0,3 | ||||||
-outlet temperature, no more | оС | 95 | ||||||
6 | Minimum inlet temperature | оС | 60 | |||||
7 | Efficiency, not less | % | 90,5 | 91 | 91 | 90,5 | 91 | 91 |
8 | Installed capacity el. motor burners, no more | kWh | 0,6 | 0,75 | 0,75 | 0,6 | 0,75 | 0,75 |
9 | Exit to operating mode, no more | min | 30 | |||||
10 | Fuel used | Gas natural low pressure | Liquid heating oil | |||||
11 | Number of explosion valves | PCS | 1 | |||||
12 | Number of safety valves | PCS | 2 | |||||
13 | Boiler aerodynamic resistance | kPa | 0,12 | 0,6 | 0,7 | 0,12 | 0,6 | 0,7 |
14 | Boiler heating surface | m2 | 16,5 | 20,2 | 22,9 | 16,5 | 20,2 | 22,9 |
15 | The noise level at the workplace does not exceed | dBA | 75 | |||||
16 | Dimensions | |||||||
- length (without burner) | mm | 1780 | 2210 | 2400 | 1780 | 2210 | 2400 | |
- width | mm | 1850 | 1850 | 1850 | 1850 | 1850 | 1850 | |
- height (without chimney) | mm | 2150 | 2150 | 2150 | 2150 | 2150 | 2150 | |
17 | Boiler weight | kg | 1410 | 1530 | 1700 | 1410 | 1530 | 1700 |
18 | Service life, not less | years | 6 | |||||
19 | Feed water requirement: | |||||||
-suspended matter, no more | mg/l | 5 | ||||||
-ring transparency | cm | 50 | ||||||
-overall rigidity, no more | mg. eq/l | 5 | ||||||
-hardness carbonate, no more | mg. eq/l | 3 | ||||||
-iron content, no more | mg/l | 0,1 | ||||||
-oxygen content, no more | mg/l | 0,03 | ||||||
-PH units, no more | pH | 8 |
Contents of the product and delivery set:
Regardless of what fuel the system is running on, the principle of operation of a hot water boiler is the same: the fuel is burned in the firebox, and through its walls, heat is transferred to the water circulating through the heating pipes. The design of hot water boilers is created in such a way as to ensure the fullest possible combustion of fuel and optimal heat transfer.
Hot water boiler burners differ depending on the type of fuel used. They can be built-in atmospheric, or replaceable supercharged. Built-in burners require only a certain type of fuel to be used. Replaceable burners are more convenient because they allow you to switch from one type of fuel to another.